Searching: Power - 135 Results Found

VESS A6000 Series VessA 6600/6800 Power consumption
Babatunde Akinkuolie posted this 21 November 2024 - Last edited 04 December 2024

The following data outlines the power consumption and thermal output for Vess A6600 and Vess A6800 systems under full load with fully populated SATA drives:

Product System status AC Input  Power Consumption (W) Thermal Output
Voltage (V) Frequency (Hz) (BTU/Hr)
Vess A6600 #1 Operation 110 60 236 805,468
230 50 228 778,164
Power on Max 110 60 538 1836,194
230 50 523 1784,999
Vess A6600 #1 Operation 110 60 229 781,577
230 50 227 774,751
Power on Max 110 60 550 1877,15
230 50 526 1795,238
Vess A6800 #2 Operation 110 60 312 1064,856
230 50 307 1047,791
Power on Max 110 60 773 2638,249
230 50 750 2559,75
Vess A6800 #2 Operation 110 60 326 1112,638
230 50 327 1116,051
Power on Max 110 60 771 2631,423
230 50 753 2569,989

 

VESS A Family VessA 7600/7800 Power consumption
Babatunde Akinkuolie posted this 21 November 2024

The following data outlines the power consumption and thermal output for Vess A7600 and Vess A7800 systems under full load with fully populated SATA drives:

Product System status AC Input  Power Consumption (W) Thermal Output
Voltage (V) Frequency (Hz) (BTU/Hr)
A7800 Operation 110 60 356 1215,028
240 50 355,9 1214,687

 

Product System status AC Input  Power Consumption (W) Thermal Output
Voltage (V) Frequency (Hz) (BTU/Hr)
A7600 Operation 110 60 262 894,206
240 50 256,3 874,752