Searching: Power - 135 Results Found

FastTrak What is PerfectRAID technology for error handling and recovery?
Ken Chou posted this 12 April 2008

http://kb.promise.com/file/download/d5938448-2bbb-48ba-94bd-a5b6009cefab

PerfectRAID™ is Promise’s patented RAID data protection technology; a suite of data protection and redundancy features built into every Promise RAID product.

  • Predictive Data Migration (PDM): Replace un-healthy disk member in array and keep array on normal status during the data transition between healthy HD and replaced HD.
  • Bad Sector Mapping and Media Patrol: These features scan the system’s drive media to ensure that even bad physical drives do not impact data availability
  • Array Error Recovery: Data recovery from bad sector or failed HD for redundant RAID
  • RAID 5/6 inconsistent data Prevent (Write Hole Table)
  • Data content Error Prevent (Read/Write Check Table)
  • Physical Drive Error Recovery
  • SMART support
  • Hard/Soft Reset to recover HD from bad status.
  • HD Powercontrol to recover HD from hung status.
  • NVRAM event logging

 

      Legacy Other VTrak E-Class event log IDs, descriptions and severity
      Ken Chou posted this 26 March 2008

      VTrak event log IDs, descriptions, severity, cause and corrective actions. 

      Updated March 26, 2008

       

      ID

      Severity

      Log

      Description

      Cause

      Action

      0x00010000

      major

      ram, nvram, buzzer, popup

      Battery temperature is above the threshold

      Enviroment is too hot or battery may be malfuctioning

      Replace battery or increase air flow

      0x00010001

      info

      ram, nvram, popup

      Battery temperature is normal

      Battery temperature is normal

      No action required

      0x00010002

      warning

      nvram, buzzer, popup

      BBU is not able to retain data in cache memory for more than 72 hrs

      Three possible causes: 1. The battery is drained. 2. The battery is being reconditioned. 3. The combination of battery and host memory is improper

      If the battery is drained or being reconditioned, allow it to recharge normally. If the wrong battery is installed, replace it with the correct one for your system or accept less than 72 hours of retention time

      0x00010003

      info

      ram, popup

      Battery capacity is normal

      Battery capacity is normal

      No action required

      0x00010004

      info

      ram, nvram, popup

      Battery is discharging

      Battery is re-conditioning

      No action is required

      0x00010005

      info

      ram, popup

      Battery is charging

      Battery is charging

      No action is required

      0x00010006

      info

      ram, popup

      Battery reconditioning is completed

      Battery reconditioning is completed

      No action is required.

      0x00010007

      major

      ram, nvram, buzzer, popup

      Battery is malfunctioning

      Battery is malfunctioning

      Try reconditioning again, or replace battery or replace battery charging circuit in fan box

      0x00010008

      info

      ram, nvram, popup

      Battery has been reconditioned successfully

      Battery has been reconditioned

      No action is required

      0x00010009

      major

      ram, nvram, buzzer, popup

      Battery reconditioning has failed

      Battery is malfunctioning

      Replace battery

      0x0001000A

      warning

      ram, nvram, buzzer, popup

      Battery is reaching the end of life

      Battery drains too many times

      Replace battery

      0x0001000B

      warning

      ram, popup

      Battery is removed

      Battery is removed

      Insert battery back

      0x0001000C

      info

      ram, popup

      Battery is inserted

      Battery is inserted

      No action is required

      0x0001000D

      warning

      ram, nvram, buzzer, popup

      Battery charging has failed

      Battery is malfuntioning

      Replace battery

      0x0001000E

      info

      ram, nvram, popup

      Battery reconditioning has started

      Battery reconditioning started

      No action is required

      0x0001000F

      warning

      ram, nvram, popup

      Battery recondition has been terminated

      Probable Battery removal or Battery malfunction

      Replace battery and try again

      0x00010011

      warning

      ram, nvram, popup

      The write policy of writeback logical drive switched from writeback to writethru

      Battery is re-conditioning or battery is malfuntioning

      Check the event log to see whether battery is re-conditioning

      0x00010012

      info

      ram, nvram, popup

      The write policy of writeback logical drive switched from writethru to writeback

      Battery holds the charge that can sustain the power to the DRAM for 72 hours and more

      No action is required

      0x00010013

      warning

      ram, nvram, popup

      Battery is charging in high temperature

      Input cause string here

      Input action string here

      0x00010014

      major

      ram, nvram, popup

      Battery cannot function with the enclosure or with the attached battery board

      Battery and battery board do not belong to this enclosure or battery cannot work with the battery board

      Input action string here

      0x00010015

      info

      ram, nvram, popup

      Logical drive writeback cache maybe enabled w/o battery support

      Users send the command to force the enclosure/system switched from write through to write back mode

      No action is required

      0x00010016

      info

      ram, popup

      Battery is fully charged

      Battery is fully charged

      No action is required

      0x00010017

      warning

      ram, popup

      Battery is not present

      No battery is detected on the controller or cooling unit during boot time

      Install the battery, or check if the battery is properly connected

      0x00010018

      critical

      ram, popup

      Battery is not accessible

      The battery has failed or it is not connected properly

      Connect the battery properly or replace it

      0x00020000

      info

      ram, popup

      Not available

      Input cause string here

      Input action string here

      0x00020001

      info

      ram, popup

      BBU flushing has started

      The system cache flushing is started

      No action is required

      0x00020002

      info

      ram, popup

      BBU flushing has ended

      The system cache flushing is complete

      No action is required

      0x00020003

      critical

      ram, nvram, popup

      BBU flushing has failed

      The system cache flushing is stopped because error

      No action is required

      0x00030000

      info

      ram, popup

      Redundancy check is started

      User started dedundancy check or BGA scheduler started it

      No action required

      0x00030001

      info

      ram, popup

      Redundancy check is completed

      Redundancy check is completed

      No action required

      0x00030002

      info

      ram, popup

      Redundancy check is paused

      User paused it, or BGA scheduler paused it, or other higer priority BGA activity paused it

      No action required

      0x00030003

      info

      ram, popup

      Redundancy check is resumed

      User resumed it, or BGA scheduler resumed it, or other higer priority BGA is completed or stopped, or resumed after reboot

      No action required

      0x00030004

      info

      ram, popup

      Redundancy check is stopped

      User stopped it, or BGA scheduler stopped it, or the logical drive is deleted, or critical, or offline

      No action required

      0x00030006

      critical

      ram, nvram, buzzer, popup

      Redundancy check is aborted due to an internal error

      System resource is not available

      Reduced system load or reboot

      0x00030007

      major

      ram, nvram, buzzer, popup

      Redundancy check encountered inconsistent block(s)

      Temporary hardware malfunction

      Check the data on the specified block(s) in inconsistent block table of the logical drive

      0x00030008

      info

      ram, popup

      Redundancy check task is queued

      Input cause string here

      Input action string here

      0x00030009

      info

      ram, popup

      Redundancy check is in progress

      Input cause string here

      Input action string here

      0x0003000A

      info

      ram, popup

      Redundancy check task is stopped internally

      LD is not online

      No action required

      0x0003000B

      info

      ram, popup

      Redundancy check is started on unsynchronized logical drive

      The user issued Redundancy check on an unsynchronized logical drive

      No action required

      0x00040000

      info

      ram, popup

      Event logging is enabled

      Event logging enabled

      None

      0x00040001

      info

      ram, popup

      Event logging is disabled

      Event logging disabled

      None

      0x00040002

      info

      ram, nvram, popup

      Event log buffer is cleared in RAM

      Event log buffer cleared

      None

      0x00040003

      info

      ram, nvram, popup

      Event log buffer is cleared in NVRAM

      Event log buffer cleared in NVRAM

      None

      0x00040004

      info

      ram, nvram, popup

      Event log buffer is cleared in MDD

      Event log buffer cleared in MDD

      None

      0x00040005

      info

      ram, nvram, popup

      The system is started

      System has been started

      None

      0x00040006

      info

      ram, nvram, popup

      The system is stopped

      System has been stopped

      None

      0x00040007

      info

      ram, popup

      The controller parameter(s) are changed by user

      The controller parameter(s) are changed by user

      None

      0x00040008

      major

      ram, nvram, popup

      The controller is reset by Watch Dog timer

      The Watch Dog hardware has reset the controller because of problems

      Update to the new firmware. If persisting, replace the controller

      0x00040009

      info

      ram, nvram, popup

      The controller has new crash information

      New crash information is found because of controller crash in the previous boot

      Contact support with the crash information to help analyze the cause of the crash

      0x00040010

      info

      ram, popup

      The controller's heart beat has started

      Partner controller has joined the clique

      None

      0x00040011

      info

      ram, popup

      The controller's heart beat has stopped

      Partner controller has been removed from the clique

      None

      0x00040012

      info

      nvram, popup

      The partner controller's heart beat has started

      Partner controller has joined the clique

      None

      0x00040013

      info

      ram, nvram, popup

      The partner controller's heart beat has stopped

      Partner controller has been removed from the clique

      None

      0x00040014

      warning

      ram, nvram, popup

      The partner controller's heart beat has skipped

      Sequence of heart beat has skipped, heart beat transport may not be reliable

      None

      0x00040015

      warning

      ram, nvram, popup

      The controller's main scheduler has frozen

      There may be hardware or firmware fault

      None

      0x00040016

      warning

      nvram, popup

      Controller has entered maintenance mode since configured physical disk seen by partner controller is not seen here

      Single ported drives may be present

      None

      0x00040017

      warning

      nvram, popup

      Controller has entered maintenance mode due to mismatch of physical disks types

      SAS cabling may not be correct

      None

      0x00040018

      warning

      nvram, popup

      Controller has entered maintenance mode due to mismatch of physical disk WWN

      There may be hardware or firmware fault

      Update to the new firmware. If persisting, replace the controller

      0x00040019

      warning

      nvram, popup

      Controller has entered maintenance mode due to mismatch of SATA Disks

      There may be cabling or hardware or firmware fault

      None

      0x00040020

      warning

      nvram, popup

      Controller has entered maintenance mode due to mismatch of Disk IDs

      There may be SAS cabling or hardware or firmware fault

      None

      0x00040021

      warning

      nvram, popup

      Controller has entered maintenance mode since no physical disks are seen as seen by Partner controller

      There may be SAS cabling hardware or firmware fault

      Fix the SAS cabling if applicable

      0x00040022

      info

      nvram, buzzer, popup

      Controller is started

      Controller is started

      None

      0x00040023

      info

      nvram, popup

      Controller is set to Active Mode

      Controller is set to Active Mode

      None

      0x00040024

      info

      nvram, popup

      Controller is set to Standby Mode

      Controller is set to Standby Mode

      None

      0x00040025

      critical

      ram, nvram, buzzer, popup

      Controller Failed Over as partner is removed

      Controller removed or shutdown by user or is bad

      Check controller if not removed or shutdown by user

      0x00040026

      critical

      ram, nvram, buzzer, popup

      Controller Failed Over as heart beat stopped

      Controller removed or shutdown by user or is bad

      Check controller if not removed or shutdown by user

      0x00040027

      critical

      ram, nvram, buzzer, popup

      Controller set to Maintenance Mode because of hardware mismatch with partner

      Controller hardware is different from that of the partner controller

      Check if this controller is of same Hardware model/configuration as the partner controller

      0x00040028

      critical

      ram, nvram, buzzer, popup

      Controller Firmware mismatch with that of the partner controller

      The Controller Firmware is of different version than the partner controller

      Auto Firmware synchronization will kick in to upgrade or downgrade the firmware

      0x00040029

      critical

      ram, nvram, buzzer, popup

      Controller set to Maintenance Mode because Firmware is flashing in the partner controller

      Controller set to Maintenance Mode because Firmware is flashing in the partner controller

      Exit out of Maintenance mode once Firmware flashing is complete on the partner controller

      0x0004002A

      info

      ram, nvram, popup

      Controller failed over to Partner controller for Firmware flashing this controller

      User initated Non Disruptive Firmware flashing has forced the failover

      none

      0x0004002B

      critical

      ram, nvram, popup

      Partner Controller was placed on reset during Fail Over processing

      Partner Controller was reset to avoid split brain scenario

      none

      0x0004002C

      critical

      ram, nvram, popup

      Controller was placed on reset during Fail Over processing

      Partner Controller was reset to avoid split brain scenario

      none

      0x0004002D

      critical

      ram, nvram, popup

      Controller set to Maintenance Mode because of flash image version mismatch with partner

      Controller flash image version is different from that of the partner controller

      Update this controller to the same flash image version as the partner controller

      0x0004002E

      critical

      ram, nvram, popup

      Controller was reset as it was not able to join the running partner controller

      The running partner controller is busy or faulty or the communication to it is faulty

      Please check the partner controller and if required replace it

      0x00040030

      critical

      ram, nvram, popup

      Controller has been set to Maintenance mode because there is a mismatch in the Controller Model or Hardware version with that of the partner controller

      Controller has been set to Maintenance mode because there is a mismatch in the Controller Model or Hardware version with that of the partner controller

      Replace this controller with the same Model and Hardware version as that of the other partner controller

      0x00040031

      critical

      ram, nvram, popup

      Controller has been set to Maintenance mode because there is a mismatch in the Controller Memory size with that of the partner controller

      Controller has been set to Maintenance mode because there is a mismatch in the Controller Memory size with that of the partner controller

      Replace this controller's memory with the same memory size as that of the other partner controller

      0x00040032

      critical

      nvram, popup

      Partner Controller has entered maintenance mode to protect user data since one of the configured physical drives was disconnected in the partner controller

      A configured physical drive was detected as removed from one of the controllers. The physical drive belongs to an array that has at least one non-redundant or critical logical drive

      Check and correct cable connections to external JBOD enclosures. Rebuild any critical logical drives. Back up array data. Replace the physical drive. Bring controller out of maintenance mode. See product manual for more information

      0x00040033

      major

      ram, nvram, popup

      The controller has reset because it encountered a firmware problem

      The controller has reset because it encountered a firmware problem

      If resets happen frequently, update to new firmware or replace the controller

      0x00050000

      info

      ram, popup

      PSU fan or blower is turned on

      fans or blowers start because either high temperature or power on default

      No action is required

      0x00050001

      info

      ram, nvram, popup

      PSU fan or blower is turned off

      fans or blowers stop because temperature dropped or stopped by users

      No action is required

      0x00050002

      info

      ram, popup

      PSU fan or blower speed is increased

      Either controller or enclosure temperature is above warning threshold

      No action is required

      0x00050003

      info

      ram, popup

      PSU fan or blower speed is decreased

      Both controller and enclosure temperature is below warning threshold

      No action is required

      0x00050004

      major

      ram, nvram, buzzer, popup

      PSU fan or blower is malfunctioning

      PSU fan is malfunctioning

      Replace PSU

      0x00050005

      info

      ram, nvram, popup

      PSU fan or blower is inserted

      PSU fan is inserted

      No action is required

      0x00050006

      warning

      ram, nvram, popup

      PSU fan or blower is removed

      PSU fan is removed

      No action is required

      0x00050007

      info

      ram, nvram, popup

      PSU fan or blower is functioning normally

      PSU fan or blower is functioning normally

      No action is required

      0x00050008

      warning

      ram, nvram, buzzer, popup

      PSU fan or blower is NOT installed

      The firmware does not detect the device existence

      Check fans or blowers

      0x00050009

      warning

      ram, popup

      PSU fan or blower status is unknown

      Can not get information from PSU fan or blower

      If persistent, replace PSU

      0x00060000

      warning

      ram, nvram, buzzer, popup

      SEP is NOT found

      SEP is NOT present or malfuntioning

      Insert or replace SEP hardware

      0x00060002

      info

      ram, popup

      SEP is found

      SEP is present or is functional

      No action is required

      0x0006000c

      info

      ram, popup

      JBOD system connected

      JBOD system is detected

      None

      0x0006000d

      critical

      ram, nvram, buzzer, popup

      JBOD system either is removed or malfunctioned

      Bad connection or users remove the connection

      Check Expander firmware and connction

      0x0006000e

      warning

      ram, nvram, buzzer

      SEP I2C device access failure

      Cannot access SEP I2C device

      None

      0x0006000f

      info

      ram, nvram

      SEP I2C device access recovered from failure

      An SEP I2C device access recovered

      If the condition persistents, replace the controller

      0x00070000

      major

      ram, nvram, buzzer, popup

      Host interface controller has detected parity error

      Input cause string here

      Input action string here

      0x00070001

      warning

      ram, buzzer, popup

      Host interface controller has detected data parity error

      Input cause string here

      Input action string here

      0x00070002

      warning

      ram, buzzer, popup

      Host interface controller has detected command parity error

      Input cause string here

      Input action string here

      0x00070003

      info

      ram, popup

      Host interface controller has detected bus reset

      Input cause string here

      Input action string here

      0x00070004

      major

      ram, nvram, buzzer, popup

      Host interface controller has encountered an unrecoverable error

      Input cause string here

      Input action string here

      0x00070005

      warning

      ram, buzzer, popup

      Host interface controller has received "abort task" command

      Input cause string here

      Input action string here

      0x00070006

      warning

      ram, buzzer, popup

      Host interface controller has received "abort task set" command

      Input cause string here

      Input action string here

      0x00070007

      warning

      ram, buzzer, popup

      Host interface controller has received "clear ACA" command

      Input cause string here

      Input action string here

      0x00070008

      warning

      ram, buzzer, popup

      Host interface controller has received "clear task set" command

      Input cause string here

      Input action string here

      0x00070009

      info

      ram, popup

      Host interface controller has received "LUN reset" command

      Input cause string here

      Input action string here

      0x0007000A

      warning

      ram, buzzer, popup

      Host interface controller is informed that the initiator has detected an error

      Input cause string here

      Input action string here

      0x0007000B

      warning

      ram, buzzer, popup

      Host interface controller has received illegal secondary identification

      Input cause string here

      Input action string here

      0x0007000C

      warning

      ram, buzzer, popup

      Host interface controller has received a message parity error

      Input cause string here

      Input action string here

      0x0007000D

      info

      ram, popup

      Host interface controller has recieved a bus reboot

      Input cause string here

      Input action string here

      0x0007000E

      info

      ram, popup

      Host interface link is up

      Input cause string here

      Input action string here

      0x0007000F

      info

      ram, popup

      Host interface link is down

      Input cause string here

      Input action string here

      0x00070010

      warning

      ram, popup

      Host interface controller has encountered an unknown error

      Input cause string here

      Input action string here

      0x00070011

      warning

      ram, popup

      Host interface controller has encountered a system error

      Input cause string here

      Input action string here

      0x00070012

      fatal

      ram, nvram, buzzer, popup

      Host interface controller has encountered a fatal error

      Input cause string here

      Input action string here

      0x00070013

      info

      ram, popup

      Host interface controller settings have changed

      Input cause string here

      Input action string here

      0x00070014

      warning

      ram, popup

      Host interface controller has received "WARM reset" command

      WARM RESET task management function is initiated from initiator, most likely initiator is trying to recover from errors or timeout period expired

      Input action string here

      0x00070015

      warning

      ram, popup

      Host interface controller has received "COLD reset" command

      COLD RESET task management function is initiated from initiator, most likely initiator is trying to recover from errors or timeout period expired

      Input action string here

      0x00070060

      warning

      ram, nvram, buzzer, popup

      Host Interface controller MU handshake failed

      Input cause string here

      Input action string here

      0x00070061

      critical

      ram, nvram, buzzer, popup

      Host Interface controller , HMU has stopped

      Input cause string here

      Input action string here

      0x00070062

      info

      ram, popup

      Host Interface controller , FMU has unloaded

      Input cause string here

      Input action string here

      0x00070080

      info

      ram, popup

      Fibre Channel host interface controller has detected bus reset

      Input cause string here

      Input action string here

      0x00070081

      info

      ram, popup

      Fibre Channel host interface controller has received "LUN reset" command

      Input cause string here

      Input action string here

      0x00070082

      fatal

      ram, nvram, buzzer, popup

      Fibre Channel host interface controller has encountered a fatal error

      Input cause string here

      Input action string here

      0x00070083

      info

      ram, popup

      Fibre Channel host interface controller link is up

      Input cause string here

      Input action string here

      0x00070084

      info

      ram, popup

      Fibre Channel controller link is down

      Input cause string here

      Input action string here

      0x00070085

      info

      ram, popup

      Fibre Channel host interface controller settings have changed

      Input cause string here

      Input action string here

      0x000700A0

      info

      ram, nvram, popup

      SCSI host interface controller settings have changed

      Input cause string here

      no action required

      0x000700A6

      info

      ram, popup

      External bus reset has occurred

      Input cause string here

      Input action string here

      0x000700A7

      info

      ram, popup

      IOC bus reset has occurred

      Input cause string here

      Input action string here

      0x000700A8

      warning

      ram, nvram, popup

      Parity error is detected during command phase

      Input cause string here

      Input action string here

      0x000700A9

      warning

      ram, nvram, popup

      Parity error is detected during message out phase

      Input cause string here

      Input action string here

      0x000700AA

      warning

      ram, nvram, popup

      CRC error is detected while receiving CMD information unit

      Input cause string here

      Input action string here

      0x000700AB

      warning

      ram, nvram, popup

      Initiator sent message for detecting an error

      Input cause string here

      Input action string here

      0x000700AC

      warning

      ram, nvram, popup

      Parity error is detected during Data Out phase

      Input cause string here

      Input action string here

      0x000700AD

      warning

      ram, nvram, popup

      CRC error is detected during Data Out phase

      Input cause string here

      Input action string here

      0x000700AE

      warning

      ram, nvram, popup

      Unknown priority reason is detected

      Input cause string here

      Input action string here

      0x000700C0

      warning

      ram, nvram, popup

      Zoning permission settings with the expander has been reset to defaults

      NA

      No action required

      0x000700C1

      warning

      ram, nvram, popup

      Zoning expander has been rebooted.

      NA

      No action required

      0x000700C2

      warning

      ram, nvram, popup

      Zoning permission settings with the expander different than expected

      Internal Zoning Permission settings exported by the expander differ from the last known setting with the SCM.

      The valid settings have been updated correctly.

      0x00080000

      info

      ram, nvram, popup

      Logical drive Initialization has started

      Logical drive Initialization was started by User

      None

      0x00080001

      info

      ram, nvram, popup

      Logical drive initialization has completed

      User requested Logical drive initialization has completed

      None

      0x00080002

      info

      ram, nvram, popup

      Logical drive initialization has paused

      Logical drive initialization has paused either internally or by user

      None

      0x00080003

      info

      ram, nvram, popup

      Logical drive initialization has resumed

      Logical drive initialization has resumed internally or by user

      None

      0x00080004

      info

      ram, nvram, popup

      Logical drive initialization has stopped

      Logical drive initialization has been stopped by user

      None

      0x00080005

      warning

      ram, nvram, buzzer, popup

      Logical drive initialization marks the logical drive offline

      Logical drive initialization marks the logical drive offline due to drive errors

      None

      0x00080006

      warning

      ram, nvram, buzzer, popup

      Logical Drive Initialization is aborted due to an internal error

      Logical Drive Initialization has stopped due to an internal error

      None

      0x00080007

      info

      ram, nvram, popup

      Quick Logical drive initialization has started

      Quick Logical drive initialization was started by user

      None

      0x00080008

      info

      ram, nvram, popup

      Quick Logical drive initialization has completed

      User requested Quick Logical drive initialization has completed

      None

      0x00080009

      info

      ram, nvram, popup

      Quick Logical drive initialization has paused

      Quick Logical drive initialization has paused either internally or by user

      None

      0x0008000A

      info

      ram, nvram, popup

      Quick Logical drive initialization has resumed

      Quick Logical drive initialization has resumed either internally or by User

      None

      0x0008000B

      info

      ram, nvram, popup

      Quick Logical drive initialization has stopped

      Quick Logical drive initialization has been stopped by User

      None

      0x0008000C

      warning

      ram, nvram, buzzer, popup

      Quick Logical drive initialization marks the logical drive offline

      Quick Logical drive initialization marks the logical drive offline due to drive errors

      None

      0x0008000D

      warning

      ram, nvram, buzzer, popup

      Quick Logical Drive Initialization is aborted due to an internal error

      Quick Logical Drive Initialization has stopped due to an internal error

      None

      0x0008000E

      info

      ram, nvram, popup

      Logical Drive Initialization is queued

      Logical Drive Initialization is queued

      None

      0x0008000F

      info

      ram, nvram, popup

      Quick Logical Drive Initialization is queued

      Quick Logical Drive Initialization is queued

      None

      0x00080010

      info

      ram, popup

      Logical Drive Initialization is in progress

      Logical Drive Initialization was started by User

      None

      0x00090000

      info

      ram, popup

      A new Logical drive has been created

      A logical drive has been added by the user to the array

      None

      0x00090001

      info

      ram, popup

      Logical drive has been deleted

      A logical drive has been deleted by the user

      None

      0x00090002

      info

      ram, popup

      Logical drive has been placed online

      All the physical drives of the array are online

      None

      0x00090003

      major

      ram, nvram, buzzer, popup

      Logical drive has been placed offline. Possible Data Loss

      One or more of the Physical Drives of the array are Offline

      Check the state of the physical drives, replace any bad drives

      0x00090004

      major

      ram, nvram, buzzer, popup

      Logical drive has been set to critical

      One or more of the Physical Drives of the array are Offline

      Check the state of the physical drives in array and rebuild the failed physical drive

      0x00090005

      info

      ram, popup

      Logical drive axle has been placed online

      None

      None

      0x00090006

      info

      ram, nvram, popup

      Rebuild marks the logical drive synchronized upon rebuild completion

      Rebuilding process made the logical drive synchronized

      None

      0x00090007

      info

      ram, nvram, popup

      Logical Drive Settings has been changed through a user command

      The User wished to change some Logical Drive Settings

      None

      0x0009000C

      major

      ram, nvram, buzzer, popup

      Logical drive has been set to degrade

      One of the Physical Drives in RAID6 LD of the array is Offline

      Check the state of the physical drives in array and rebuild the failed physical drive

      0x0009000D

      major

      ram, nvram, popup

      One of the Error Table (Read Check Table (RCT), Write Check Table (WCT) or Inconsistent Block Table (IBT)) of a logical drive has been cleared by the user

      User has cleared the Error Table

      None

      0x000B0000

      info

      ram, popup

      Media patrol is started

      User or BGA scheduler started it

      No action required

      0x000B0001

      info

      ram, popup

      Media patrol is completed

      Media patrol is completed

      No action required

      0x000B0002

      info

      ram, popup

      Media patrol is paused

      User or BGA scheduler or other higer priority BGA activity paused it

      No action required

      0x000B0003

      info

      ram, popup

      Media patrol is resumed

      User or BGA scheduler or other higer priority BGA is completed or stopped

      No action required

      0x000B0004

      info

      ram, popup

      Media patrol is stopped

      User stopped it, or BGA scheduler stopped it, or all array(s) and spare(s) with media patrol enabled are deleted

      No action required

      0x000B0006

      critical

      ram, nvram, buzzer, popup

      Media Patrol is aborted due to an internal error

      System resource is not available

      Reduced system load or reboot

      0x000B0007

      info

      ram, popup

      Media Patrol is queued

      Input cause string here

      Input action string here

      0x000B0008

      info

      ram, popup

      Media Patrol is stopped internally

      All array with MP enabled is deleted / removed

      No action required

      0x000B0009

      info

      ram, popup

      Media Patrol is in progress

      Input cause string here

      No action required

      0x000C0000

      info

      ram, nvram, popup

      RAID migration has started

      Input cause string here

      Input action string here

      0x000C0001

      info

      ram, nvram, popup

      RAID migration has completed

      Input cause string here

      Input action string here

      0x000C0002

      info

      ram, nvram, popup

      RAID migration has paused

      Input cause string here

      Input action string here

      0x000C0003

      info

      ram, nvram, popup

      RAID migration has resumed

      Input cause string here

      Input action string here

      0x000C0004

      info

      ram, nvram, popup

      RAID migration has stopped

      Input cause string here

      Input action string here

      0x000C0005

      warning

      ram, nvram, buzzer, popup

      RAID migration has encountered a physical disk error

      Input cause string here

      Input action string here

      0x000C0006

      warning

      ram, nvram, buzzer, popup

      RAID migration is aborted due to an internal error

      Input cause string here

      Input action string here

      0x000C0007

      info

      ram, nvram, popup

      RAID migration is queued

      Input cause string here

      Input action string here

      0x000C0008

      info

      ram, nvram, popup

      Migration has detected Stale NV Watermark

      Input cause string here

      Input action string here

      0x000C0009

      info

      ram, nvram, popup

      Migration has cleared Stale NV Watermark

      Input cause string here

      Input action string here

      0x000C000A

      info

      ram, nvram, popup

      Array was made Incomplete due to missing NV Watermark

      Input cause string here

      Input action string here

      0x000C000B

      info

      ram, nvram, popup

      User has accepted Incomplete Array. (caused by missing NV Watermark)

      Input cause string here

      Input action string here

      0x000C000C

      info

      ram, popup

      RAID migration is in progress

      Input cause string here

      Input action string here

      0x000D0000

      info

      ram, popup

      Physical Disk is marked online

      Physical Disk was used to create the configuration

      No Action required

      0x000D0001

      info

      ram, popup

      Physical Disk is marked offline

      Physical Disk was marked offline by user or internally due to errors

      Replace the physicla disk with a new disk

      0x000D0002

      major

      ram, nvram, buzzer, popup

      Physical Disk is marked as DEAD

      Physical Disk is marked as DEAD due to drive errors

      Replace the physical disk with a new disk

      0x000D0003

      info

      ram, popup

      Physical Disk has been reset

      Physical Disk has been reset due to command time out

      Replace the physical disk with a new disk

      0x000D0004

      info

      ram, popup

      Physical Disk is assigned as a global spare

      Physical Disk is assigned as a global spare

      No action required

      0x000D0005

      info

      ram, popup

      Global Spare has been deleted

      Global Spare has been deleted

      None

      0x000D0006

      info

      ram, popup

      Physical Disk is no longer assigned as a global spare

      Physical Disk was used as data member to rebuild one of the members of the array

      None

      0x000D0007

      info

      ram, popup

      Physical Disk is assigned as a dedicated spare

      Physical Disk is assigned as a dedicated spare by User

      None

      0x000D0008

      info

      ram, popup

      Dedicated Spare has been deleted

      Dedicated Spare has been deleted by User

      None

      0x000D0009

      info

      ram, popup

      Physical Disk is no longer assigned as a dedicated spare

      Physical Disk was used as data member to rebuild one of the members of the dedicated array

      None

      0x000D000A

      info

      ram, popup

      Physical Disk has been inserted

      Physical Disk has been inserted by User

      None

      0x000D000B

      info

      ram, popup

      Physical Disk has been removed

      Physical Disk has been removed by User

      Insert a new physical disk

      0x000D000C

      info

      ram, popup

      Command on phyiscal disk has been re-tried

      Command on phyiscal disk has been re-tried due to drive not responding to the command

      None

      0x000D000D

      minor

      ram, nvram, buzzer, popup

      Physical disk ECC error is detected

      Physical disk ECC error is detected due to bad medium on the disk

      Replace the physical disk with a new disk

      0x000D000E

      minor

      ram, nvram, buzzer, popup

      Physical disk CRC error is detected

      Physical Disk CRC error is detected due to bad medium on the disk

      Replace the physical disk with a new disk

      0x000D000F

      minor

      ram, nvram, buzzer, popup

      Bad sector is found on physical disk

      Bad sector is found on physical disk due to medium errors on the disk

      Replace the physical disk with a new disk

      0x000D0010

      minor

      ram, nvram, buzzer, popup

      Error is detected in remap sectors

      Error is detected in remap sectors due to medium errors in the disk

      None

      0x000D0011

      minor

      ram, nvram, buzzer, popup

      Command times out on physical disk

      Command times out on physical disk

      Replace the physical disk with a new disk

      0x000D0012

      warning

      ram, buzzer, popup

      Physical disk negotiation speed is decreased

      Physical disk negotiation speed is decreased as the disk does not support higher speed

      None

      0x000D0013

      warning

      ram, popup

      Previously configured disk is no longer found

      Previously configured disk is no longer found as that disk is not present

      Insert the previously configured disk in to the system

      0x000D0014

      warning

      ram, nvram, popup

      A physical disk has encountered an unknown (non-ECC) media error

      A physical disk has encountered an unknown (non-ECC) media error

      Replace the physical disk with a new disk

      0x000D0015

      warning

      ram, nvram, popup

      A physical disk has encountered PFA condition

      A physical disk has encountered PFA condition

      Replace the physical disk with a new disk

      0x000D0016

      info

      ram, popup

      A configured dead physical disk has been inserted

      A configured dead physical disk has been inserted

      Replace the physical disk with a new disk

      0x000D0017

      warning

      ram, nvram, popup

      A physical disk Page 0 settings has changed

      A physical disk Page 0 settings was changed by User

      None

      0x000D0018

      warning

      ram, nvram, popup

      Physical disk page 1 (SATA related) settings have changed

      Physical disk page 1 (SATA related) settings was changed by User

      None

      0x000D001A

      major

      ram, nvram, buzzer, popup

      Physical Disk is marked as DEAD due to removal

      Physical Disk is marked as DEAD due to removal

      Insert a new physical disk in to the slot

      0x000D001b

      major

      ram, nvram, buzzer, popup

      Physical Disk is marked as DEAD due to the failure of Reassign sectors comand to the disk

      Physical Disk is marked as DEAD due to the failure of Reassign sectors comand to the disk

      Replace the disk with new physical disk

      0x000D001c

      major

      ram, nvram, buzzer, popup

      Physical Disk is marked as DEAD due to PFA condition of the disk

      >Physical Disk is marked as DEAD due to PFA condition of the disk

      Replace the disk with new physical disk

      0x000D001d

      major

      ram, nvram, buzzer, popup

      Physical Disk is marked as DEAD due to forced offline state

      Physical Disk is marked as DEAD due to forced offline state by User

      Replace the disk with new physical disk

      0x000D001e

      warning

      ram, nvram, popup

      One of The Physical disk Path has failed

      One of The Physical disk Path has failed

      None

      0x000D001f

      warning

      ram, nvram, popup

      Physical disk page 3 (SAS related settings) have changed

      Physical disk page 3 (SAS related settings) was changed by User

      None

      0x000D0020

      warning

      ram, nvram, popup

      Physical disk seen by partner controller not seen here

      Possibly single ported drives present or incorrect SAS Cabling

      Fix the SAS cabling if not single ported drives

      0x000D0021

      warning

      ram, nvram, popup

      Single Ported Physical disk seen by Partner controller not seen here

      Possibly single ported drives present

      None

      0x000D0022

      warning

      ram, nvram, popup

      Physical Disk reported not ready

      Physical Disk reported not ready

      Replace the physical disk with a new disk

      0x000E0000

      warning

      ram, buzzer, popup

      PSU is NOT inserted

      PSU is NOT inserted

      Insert PSU

      0x000E0001

      warning

      ram, nvram, buzzer, popup

      PSU is off

      PSU is turned off or power cable is unplugged

      Turn on power or plug in power cable

      0x000E0002

      info

      ram, nvram, buzzer, popup

      PSU is on

      PSU is on

      No action is required

      0x000E0003

      info

      ram, nvram, popup

      PSU is installed and turned on

      PSU is installed and is switched on

      No action is required

      0x000E0004

      warning

      ram, nvram, popup

      PSU is installed and turned off

      PSU is installed but it is switched off

      Check PSU switch

      0x000E0005

      info

      ram, nvram, popup

      PSU is functional and turned on

      PSU is operational and is switched on

      No action is required

      0x000E0006

      warning

      ram, nvram, popup

      PSU is functional and turned off

      PSU is operational but is switched off

      Check PSU switch

      0x000E0007

      major

      ram, nvram, popup

      PSU is malfunctioning and turned on

      PSU is malfunctional with power switched on

      Replace PSU

      0x000E0008

      major

      ram, nvram, popup

      PSU is malfunctioning and turned off

      PSU is malfunctional with power switched off

      Replace PSU

      0x000E0009

      warning

      ram, nvram, popup

      PSU has been removed

      The firmware does not detect the specific PSU existence

      Check PSU

      0x000E0010

      critical

      ram, nvram, buzzer, popup

      PSU 12V power is out of the threshold range

      The firmware detects 12V power is out of range

      Replace PSU

      0x000E0011

      critical

      ram, nvram, buzzer, popup

      PSU 5V power is out of the threshold range

      The firmware detects 5V power is out of range

      Replace PSU

      0x000E0012

      critical

      ram, nvram, buzzer, popup

      PSU 3.3V power is out of the threshold range

      The firmware detects 3.3V power is out of range

      Replace PSU

      0x000E0013

      info

      ram, nvram, popup

      PSU 3.3V power is within the normal range

      The firmware detects 3.3V power is within the range

      No action is required

      0x000E0014

      info

      ram, nvram, popup

      PSU 5V power is within the normal range

      The firmware detects 5V power is within the range

      No action is required

      0x000E0015

      info

      ram, nvram, popup

      PSU 12V power is within the normal range

      The firmware detects 12V power is within the range

      No action is required

      0x000E0016

      critical

      ram, nvram, popup

      PSU is critical. This may cause instability of the system

      Unsupported PSU or unstable power

      Check the power to the PSU, or replace the PSU with the supported model

      0x000F0000

      info

      ram, nvram, popup

      Rebuild is started

      User started rebuild, or auto-rebuild is started

      No action required

      0x000F0001

      info

      ram, nvram, popup

      Rebuild is completed

      Rebuild is completed on the physical drive

      No action required

      0x000F0002

      warning

      ram, popup

      Rebuild is paused

      User paused it

      Resume rebuild as soon as possible

      0x000F0003

      info

      ram, popup

      Rebuild is resumed

      User resumed it or rebuild is resumed after reboot

      No action required

      0x000F0004

      warning

      ram, nvram, popup

      Rebuild is stopped

      User stopped it, or array is deleted

      If user stopped it, restart rebuild as soon as possible

      0x000F0007

      critical

      ram, nvram, buzzer, popup

      Rebuild is aborted

      System resource is not available

      Reduce system load or reboot

      0x000F0009

      info

      ram, nvram, popup

      Rebuild is queued

      Input cause string here

      Input action string here

      0x000F000A

      info

      ram, nvram, popup

      Transition is started

      User started it or auto-transition started

      No action required

      0x000F000B

      info

      ram, nvram, popup

      Transition is completed

      Transition is completed

      No action required

      0x000F000C

      info

      ram, popup

      Transition is paused

      User paused it or other higher priority BGA scheduler is running

      User resume as needed

      0x000F000D

      info

      ram, popup

      Transition is resumed

      User resumed it,or it is resumed after reboot

      No action required

      0x000F000E

      info

      ram, nvram, popup

      Transition is stopped

      User stopped it

      No action required

      0x000F000F

      info

      ram, nvram, popup

      Transition is switched to rebuild

      Source physical drive is removed or dead

      No action required

      0x000F0010

      warning

      ram, nvram, popup

      Auto rebuild can not start

      The capacity of unconfigured physical drive is not capable of rebuild

      Replace a drive with proper capacity

      0x000F0011

      warning

      ram, nvram, popup

      Rebuild stopped internally

      Logical drive is offline

      No action required

      0x000F0012

      info

      ram, popup

      Rebuild is in progress

      Input cause string here

      No action required

      0x000F0013

      info

      ram, popup

      Transition is in progress

      Input cause string here

      No action required

      0x00100000

      minor

      ram, nvram, buzzer, popup

      SMART error is received

      Input cause string here

      Input action string here

      0x0011000A

      info

      ram, popup

      Subsystem parameter(s) are changed by user

      Subsystem parameter(s) are changed by user

      None

      0x0011000B

      info

      ram, popup

      System is set to Redundant mode

      A partner controller has joined to form High Availability

      None

      0x0011000C

      major

      ram, nvram, buzzer, popup

      System is set to Critical mode

      The partner controller is no longer accessible

      Check the partner controller

      0x0011000D

      info

      ram, popup

      System is set to Non-Redundant mode

      Only one controller is present in the system

      None

      0x0011000E

      info

      ram, nvram, popup

      The Subsystem is started

      The Subsystem has started

      None

      0x0011000F

      info

      ram, nvram, popup

      The Subsystem is stopped

      The Subsystem has stopped

      None

      0x00120000

      info

      ram, popup

      Synchronization is started

      The logical drive is created

      No action is required

      0x00120001

      info

      ram, popup

      Synchronization is completed

      Synchronization is completed

      No action is required

      0x00120002

      info

      ram, popup

      Synchronization is paused

      Higher priority BGA activity such as PDM or RC on the logical drive(s) on the same array is running

      No action required

      0x00120003

      info

      ram, popup

      Synchronization is resumed

      Higher priority BGA activity is completed or it is resumed after reboot

      No action required

      0x00120004

      info

      ram, popup

      Synchronization is stopped

      Logical drive is deleted, or critical, or offline. It could be also initialization or migration started

      No action required

      0x00120005

      critical

      ram, nvram, buzzer, popup

      Synchronization is aborted due to an internal error

      System resource is not available

      Reduce system load or reboot

      0x00120006

      info

      ram, popup

      Synchronization is queued

      Sync is already running on some other LD in same array

      None

      0x00120008

      info

      ram, popup

      Synchronization is stopped internally

      LD not online or Higher priority task like LDI is started or delete LD/array

      None

      0x00130000

      info

      ram, popup

      New disk array has been created

      A new disk array has been created by the user

      None

      0x00130001

      info

      ram, popup

      Disk array has been deleted

      A disk array has been deleted by the user

      None

      0x00130002

      info

      ram, popup

      Disk array has been added

      A new disk array has been added to the controller by adding new Physical drives to the enclosure

      None

      0x00130003

      warning

      ram, buzzer, popup

      Disk array has been removed

      A disk array has been removed from the controller by removing Physical Drives from the enclosure

      If the drives were not intentionally removed, check to see if the drives are properly inserted in the enclosure

      0x00130004

      info

      ram, popup

      Disk array settings have been changed

      Disk array settings have been changed through user intervention

      None

      0x00130005

      info

      ram, nvram, popup

      Disk array is transport ready

      User requested to make a disk array transport ready

      Disk array is ready for transport. Remove Physical drives in disk array and move them to a different subsystem. To cancel Transport Ready Status, remove and reinsert the drives in the disk array.

      0x00140000

      info

      ram, popup

      Drive interface controller is found

      Input cause string here

      Input action string here

      0x00140001

      info

      ram, popup

      Drive interface controller is NOT found

      Input cause string here

      Input action string here

      0x00140002

      info

      ram, popup

      Drive interface diagnostics has passed

      Input cause string here

      Input action string here

      0x00140003

      info

      ram, nvram, popup

      Drive interface diagnostics has failed

      Input cause string here

      Input action string here

      0x00140004

      info

      ram, nvram, popup

      Drive interface controller has generated a general parity error

      Input cause string here

      Input action string here

      0x00140005

      info

      ram, nvram, popup

      Drive interface controller has generated a data parity error

      Input cause string here

      Input action string here

      0x00150000

      info

      ram, nvram, popup

      Online Capacity Expansion has started

      Input cause string here

      Input action string here

      0x00150001

      info

      ram, nvram, popup

      Online Capacity Expansion has completed

      Input cause string here

      Input action string here

      0x00150002

      info

      ram, nvram, popup

      Online Capacity Expansion has paused

      Input cause string here

      Input action string here

      0x00150003

      info

      ram, nvram, popup

      Online Capacity Expansion has resumed

      Input cause string here

      Input action string here

      0x00150004

      info

      ram, nvram, popup

      Online Capacity Expansion has stopped

      Input cause string here

      Input action string here

      0x00150005

      fatal

      ram, nvram, buzzer, popup

      Online Capacity Expansion has encountered a physical disk error

      Input cause string here

      Input action string here

      0x00150006

      fatal

      ram, nvram, buzzer, popup

      Online Capacity Expansion is aborted due to an internal error

      Input cause string here

      Input action string here

      0x00150007

      info

      ram, nvram, popup

      Online Capacity Expansion is queued

      Input cause string hereOnline Capacity Expansion task is queued

      Input action string here

      0x00160000

      info

      ram, nvram, popup

      RAID Level Migration has started

      Input cause string here

      Input action string here

      0x00160001

      info

      ram, nvram, popup

      RAID Level Migration has completed

      Input cause string here

      Input action string here

      0x00160002

      info

      ram, nvram, popup

      RAID Level Migration has paused

      Input cause string here

      Input action string here

      0x00160003

      info

      ram, nvram, popup

      RAID Level Migration has resumed

      Input cause string here

      Input action string here

      0x00160004

      info

      ram, nvram, popup

      RAID Level Migration has stopped

      Input cause string here

      Input action string here

      0x00160005

      fatal

      ram, nvram, buzzer, popup

      RAID Level Migration has encountered a physical disk error

      Input cause string here

      Input action string here

      0x00160006

      fatal

      ram, nvram, buzzer, popup

      RAID Level Migration is aborted due to an internal error

      Input cause string here

      Input action string here

      0x00160007

      info

      ram, nvram, popup

      RAID Level Migration is queued

      Input cause string here

      Input action string here

      0x00170000

      info

      ram, nvram, popup

      Stripe Level Migration has started

      Input cause string here

      Input action string here

      0x00170001

      info

      ram, nvram, popup

      Stripe Level Migration has completed

      Input cause string here

      Input action string here

      0x00170002

      info

      ram, nvram, popup

      Stripe Level Migration has paused

      Input cause string here

      Input action string here

      0x00170003

      info

      ram, nvram, popup

      Stripe Level Migration has resumed

      Input cause string here

      Input action string here

      0x00170004

      info

      ram, nvram, popup

      Stripe Level Migration has stopped

      Input cause string here

      Input action string here

      0x00170005

      fatal

      ram, nvram, buzzer, popup

      Stripe Level Migration has encountered a physical disk error

      Input cause string here

      Input action string here

      0x00170006

      fatal

      ram, nvram, buzzer, popup

      Stripe Level Migration is aborted due to an internal error

      Input cause string here

      Input action string here

      0x00170007

      info

      ram, nvram, popup

      Stripe Level Migration is queued

      Input cause string here

      Input action string here

      0x00190000

      info

      ram, popup

      Resource is NOT available

      Input cause string here

      Input action string here

      0x00190001

      info

      ram, popup

      Resource is NOT available

      Input cause string here

      Input action string here

      0x00190002

      info

      ram, popup

      Resource is NOT available

      Input cause string here

      Input action string here

      0x00190003

      info

      ram, popup

      Resource is NOT available

      Input cause string here

      Input action string here

      0x001A0000

      info

      ram, popup

      Blowers or PSU fans have started

      The firmware starts blowers or PSU fans

      No action is required

      0x001A0001

      info

      ram, popup

      Blowers or PSU fans have stopped

      The firmware stops blowers or PSU fans

      No action is required

      0x001A0002

      info

      ram, popup

      Blower or PSU fan speed is increased

      Temperatures Increased

      No action is required

      0x001A0003

      info

      ram, popup

      Blower or PSU fan speed is decreased

      Temperatures dropped back to normal

      No action is required

      0x001A0004

      minor

      ram, nvram, buzzer, popup

      Blowers or PSU fans are NOT functioning

      The firmware detects blowers or PSU fans with a speed of 0 or out of control

      Replace blower or PSU fans

      0x001A0005

      info

      ram, popup

      Blowers or PSU fans have been inserted

      The firmware detects the specific blowers or PSU existence

      No action is required

      0x001A0006

      info

      ram, popup

      Blowers or PSU fans have been removed

      The firmware is not able to detect the existence of the blower or the PSU fan, but exist in the previous status

      Check blowers or PSU fans

      0x001A0007

      info

      ram, nvram, popup

      Blowers or PSU fans are functioning normally

      The blower or the PSU fan are detected with good status

      No action is required

      0x001A0008

      warning

      ram, nvram, buzzer, popup

      Blowers or PSU fans are NOT installed

      The firmware does not detect existenc of blowers or PSU fans

      Check blowers or PSU fans

      0x001A0009

      warning

      ram, nvram, buzzer, popup

      Blower or PSU fan status is unknown

      The firmware is not able to read blowers or PSU fans information but detects the existence

      Check blowers or PSU fans

      0x001B0000

      info

      ram, nvram, popup

      PDM is started

      User started it or the drive in the array has PFA condition

      No action required

      0x001B0001

      info

      ram, nvram, popup

      PDM is completed

      PDM is completed

      None

      0x001B0002

      info

      ram, popup

      PDM is paused

      User paused it or higher priority BGA activity started

      If user paused, resumed it

      0x001B0003

      info

      ram, popup

      PDM is resumed

      User resumed it or higher priority BGA activity is completed or it is resumed after rebooted

      No action required

      0x001B0004

      info

      ram, popup

      PDM is stopped

      User stopped it or destination physical drive is removed or dead

      No action required

      0x001B0009

      info

      ram, nvram, popup

      PDM is swtiched to rebuild

      Source drive is removed or dead

      No action required

      0x001B000a

      info

      ram, popup

      PDM is stopped internally

      Destination drive is removed or used for rebuild

      No action required

      0x001B000B

      info

      ram, popup

      PDM is in progress

      Input cause string here

      No action required

      0x001D0000

      info

      ram, popup

      Spare check started on the given spare drive

      Spare check started either manually by the user or started by SW scheduler

      No action required

      0x001D0001

      info

      ram, popup

      Spare check completed successfully on the given spare drive

      Spare check completed successfully on the given spare array

      No action required

      0x001e0000

      critical

      ram, nvram, buzzer, popup

      Enclosure temperature is above the threshold

      The system temperature is above the preset threshold

      Check blowers and fans

      0x001e0001

      critical

      ram, nvram, buzzer, popup

      Enclosure temperature is above the critical threshold

      The system temperature is above enclosure critical threshold

      Check blowers and fans

      0x001e0002

      warning

      ram, nvram, buzzer, popup

      Enclosure temperature is above the warning threshold

      The enclosure temperature is above enclosure warning threshold

      Check blowers and fans

      0x001e0003

      info

      ram, nvram, popup

      Enclosure temperature is within the normal range

      The system temperature drops below the enclosure warning threshold

      No Action is required

      0x001e0004

      critical

      ram, nvram, buzzer, popup

      Controller temperature is above the critical threshold

      The controller temperature is above controller critical threshold

      Check blowers and fans

      0x001e0005

      warning

      ram, nvram, buzzer, popup

      Controller temperature is above the warning threshold

      The controller temperature is above controller warning threshold

      Check blowers and fans

      0x001e0006

      info

      ram, nvram, popup

      Controller temperature is within the normal range

      The controller temperature drops below the controller warning threshold

      No action is required

      0x001e0007

      critical

      ram, nvram

      Shut down PSUs due to enclosure or controller temperature over threshold

      The PSUs shut down because temperatures exceed the protection threshold

      Refer to the troubleshooting section of the product manual

      0x001F0000

      info

      ram, popup

      Firmware update is started

      Firmware update is started

      No action required

      0x001F0001

      info

      ram, popup

      Firmware update is complete

      Firmware update is complete

      No action required

      0x001F0002

      warning

      ram, popup

      Firmware update is fail

      Firmware update is fail

      No action required

      0x001F0003

      info

      ram, nvram, popup

      Backend expander firmware upgrade is completed

      NA

      No action required

      0x001F0004

      info

      ram, nvram, popup

      Frontend expander firmware upgrade is completed

      NA

      No action required

      0x001F0005

      major

      ram, nvram, popup

      Backend expander firmware upgrade failed

      Backend (Interposer) upgrade cannot be completed successfully

      Retry the firmware upgrade

      0x001F0006

      major

      ram, nvram, popup

      Frontend expander firmware upgrade failed

      Frontend expander upgrade cannot be completed successfully

      Retry the firmware upgrade

      0x001F0007

      info

      ram, nvram, popup

      Backend expander firmware upgrade is started

      NA

      No action required

      0x001F0007

      info

      ram, nvram, popup

      Frontend expander firmware upgrade is started

      NA

      No action required

      0x00220000

      info

      ram

      Blade Server Inserted

      Blade Server was plugged in

      No action required

      0x00220001

      info

      ram

      Blade Server Removed

      Blade Server was plugged out

      No action required

       

       

      ©2008 Promise Technology, Inc. All Rights Reserved.

      No part of this document may be reproduced or transmitted in any form without the expressed, written permission of Promise Technology, Inc.

       