Searching: Power - 135 Results Found

VESS A8000 Series Vess A8600 Power consumption
Babatunde Akinkuolie posted this 04 December 2024

These numbers are derived from fully populated Vess A8600 chassis utilizing SATA drives under full load:

Product System status AC Input  Power Consumption (W) Thermal Output
Voltage (V) Frequency (Hz) (BTU/Hr)
A8600 Operation 110 60 259 883.967
240 50 256.9 876.800

 

Product System status AC Input  Power Consumption (W) Thermal Output
Voltage (V) Frequency (Hz) (BTU/Hr)
A8600 Standby Mode 110 60 211 720.143
240 50 210.1 717.071

 

Product System status AC Input  Power Consumption (W) Thermal Output
Voltage (V) Frequency (Hz) (BTU/Hr)
A8600 Power on Max 110 60 446 1522.198
240 50 432.3 1475.440

VESS A6000 Series Vess A6800p Power consumption
Babatunde Akinkuolie posted this 04 December 2024

These numbers are derived from fully populated Vess A6800P chassis utilizing SATA drives under full load:

Product System status AC Input  Power Consumption (W) Thermal Output
Voltage (V) Frequency (Hz) (BTU/Hr)
A6800p Operation 110 60 315 1075.095
240 50 312.9 1067.928

 

Product System status AC Input  Power Consumption (W) Thermal Output
Voltage (V) Frequency (Hz) (BTU/Hr)
A6800p Standby Mode 110 60 243 829.359
240 50 243.3 830.383

 

Product System status AC Input  Power Consumption (W) Thermal Output
Voltage (V) Frequency (Hz) (BTU/Hr)
A6800p Power on Max 110 60 556 1897.628
240 50 549 1873.737

Close