PegasusPro Family PegasusPro R8/R16 Power Consumption
Babatunde Akinkuolie posted this 29 October 2024

PegasusPro Power Consumption
 
PegasusPro R8
System status Input Voltage  Frequency Current
(A)
Power Consumption
(W)
Thermal Output
    (BTU/Hr)
Operation 110V 60Hz 2.394 262 894.206
230V 50Hz 1.133 259.2 884.6496
Power on Max 110V 60Hz 2.285 251 856.663
230V 50Hz 1.072 244.7 835.1611
           
            
           
           
PegasusPro R16
System status Input Voltage  Frequency Current
(A)
Power Consumption
(W)
Thermal Output
    (BTU/Hr)
Operation 110V 60Hz 3.766 410 1399.33
230V 50Hz 1.738 393.2 1341.9916
Power on Max 110V 60Hz 5.81 637 2174.081
230V 50Hz 2.702 607 2071.691

 

Note:

Power on Max: The highest value at the moment of Power-on

PegasusPro Family How to Repair a File System in PegasusProR8/R16
Babatunde Akinkuolie posted this 29 October 2024

In certain instances, the file system of the PegasusPro R8/R16 may be susceptible to corruption, typically due to abnormal shutdowns, power failures, or hard disk malfunctions. The extent of file system corruption can vary, and in unfortunate cases, this may result in the failure to load the team volume and its folders, leading to filesystem errors.

 To address and repair a corrupted file system, please follow these steps:

  • Log in to the unit's WebPAM Insight.
  • Navigate to Storage -> Team.
  • Locate the desired Volume, click the three dots underneath, and select "Start Repair."
  • Choose "Normal" as the Repair Mode to initiate the filesystem repair process.

Important Considerations:

  •  During the file system repair, the volume will be unmounted and inaccessible.
  • All team folders associated with the team volume will be temporarily unavailable.
  • The duration of the file system repair process may vary based on the size of the volume.
  • In the event that the Normal mode repair proves unsuccessful, consider attempting the "Force" mode to repair the filesystem.

 

 

Close